VIDEO:
30 SECOND
PART BUILDER
EXPLAINED
- SMC Home
- Airline Equipment
- Clean Room Products
- AW
- AW20~40, Filter/Regulator Combination, Special Applications
AW20~40, Filter/Regulator Combination, Special Applications
Clean series 10-AW filter regulators have fluorine grease, are assembled and inspected in a workshop, and have clean packaging (products are sealed in anti-static double bags after the surface has been blown with clean air). The 10-AW series has a particle generation grade of 1, and is available with port sizes from 1/8 to 3/4 (Rc, G or NPT threads).
How to order
Filter Regulator
AW-BSeries
Filter Regulator with
Backflow Function
10-
21-
AW
K-BSeries
10-
21-
How to Order
K F10 AW B30 03 BG JN
K F21 AW B30 03 BG JN
Clean series
∗"J" must always
be selected.
Copper, fluorine and silicone-free +
Low particle generation
Filter regulator
q r t yw e
•
Option/Semi-standard: Select one each for a to g.
• Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order.
+
+
+
Symbol
Nil
K
Note 1)
Nil
B
Note 5)
H
With backflow
function
Mounting
w
Nil
N
Note 2)
F
Note 3)
Thread type
Description
Without backflow function
With backflow function
Rc
NPT
G
1/8
1/4
3/8
1/2
3/4
1
01
02
03
04
06
10
Port size
r
t
Option
Note 4)
a
Without mounting option
With bracket
With set nut (for panel mounting)
Body size
20 40 6030
+
Nil
G
Pressure gauge
b
Without pressure gauge
Round type pressure gauge (without limit indicator)
q
e
1079
A
Symbol
Description
Body size
20 40 6030
+
Semi-standard
Nil
1
Note 6)
Set pressure
c
0.05 to 0.85 MPa setting
0.02 to 0.2 MPa setting
+
Nil
2
6
8
C
6C
Bowl
d
Polycarbonate bowl
Metal bowl
Nylon bowl
Metal bowl with level gauge
With bowl guard
Nylon bowl with bowl guard
+
J
Drain port
Note 7)
Drain guide 1/8
Drain guide 1/4
+
Nil
N
Exhaust
mechanism
e
Relieving type
Non-relieving type
+
Nil
R
Flow direction
f
Flow direction: Left to right
Flow direction: Right to left
+
Nil
Z
Note 8)
Pressure unit
g
Name plate, caution plate for bowl, and pressure gauge in imperial units: MPa
Name plate: psi, Caution plate for bowl: psi, °F , Pressure gauge: Both MPa and psi
Note 9)
q
Note 1) When using a non-relieving type with a backflow function, if the inlet pressure is increased slowly, the inlet pressure may continue to the outlet side.
Note 2) Drain guide is NPT1/8 (applicable to the 10-/21-AW20(K)-B) and NPT 1/4 (applicable to the 10-/21-AW30(K)-B to AW60(K)-B).
Note 3)
Drain guide is G1/8 (applicable to the 10-/21-AW20
(
K
)-B
) and G 1/4 (applicable to the 10-/21-AW30
(
K
)-B
to AW60
(
K
)-B
).
Note 4) Option B, G, H are not assembled and supplied loose at the time of shipment.
Note 5) Assembly of a bracket and set nuts (10-/21-AW20(K)-B to AW40(K)-B) Including 2 mounting screws for the 10-/21-AW60(K)-B
Note 6) The only difference from the standard specifications is the adjusting spring for the regulator. It does not restrict the setting of 0.2 MPa or more. When
the pressure ga
uge is attached, a 0.4 MPa pressure gauge will be fitted.
Note 7) Be sure to select “J” drain guide. Without a valve function
Note 8) For thread type: NPT. This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.)
Note 9)
: For thread type: NPT only
Bracket assembly
Note 1)
Set nut
Pressure
gauge
Note 4)
Port size
Pressure gauge port size
Fluid
Ambient and fluid temperature
Proof pressure
Maximum operating pressure
Set pressure range
Nominal filtration rating
Drain capacity (cm
3
)
Drain guide port size
Construction
Grease
Cleanliness class (ISO class)
Standard
0.02 to 0.2 MPa setting
Model
Option
Model
10-/21-AW20(K)-B
AW23P-270AS
AR23P-260S
10-/21-AW30(K)-B
AR33P-270AS
AR33P-260S
10: G49-10-01, 21: G49-10-01-MS-X3
10: G49-4-01, 21: G49-4-01-MS-X3
10-/21-AW40(K)-B
AR43P-270AS
AR43P-260S
10-/21-AW40(K)-06-B
10-/21-AW60(K)-B
10-/21-AW20(K)-B 10-/21-AW30(K)-B 10-/21-AW40(K)-B
10-/21-AW40(K)-06-B
10-/21-AW60(K)-B
1/8, 1/4 1/4, 3/8
1/8
1/4, 3/8, 1/2 3/4
Air
–5 to 60°C (with no freezing)
1.5 MPa
1.0 MPa
0.05 to 0.85 MPa
5 µm
Relieving type
10-: Fluorine grease
21-: Lithium soap based grease
10-: Class 3
21-: Class 3
3/4, 1
8 25 45 45
1/8 1/4
45
Options/Part No.
Standard Specifications
Note 1) Assembly of a bracket and set nuts. Including 2 mounting screws for the AW60(K)-B
Note 2) Please consult with SMC regarding the set nuts for the AW60(K)-B.
Note 3) in part numbers for a round pressure gauge indicates a pipe thread type. No indication is necessary for R; however, indicate N for NPT.
Please contact SMC regarding the pressure gauge supply for both MPa and psi unit specifications.
Note 4) in part numbers for a round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N for NPT.
Please contact SMC regarding the connection thread NPT and pressure gauge supply for psi unit specifications.
Note 9) Note 9) Note 9)
Round
type
Note 3)
AW62P-270AS
—
Note 2)
Filter Regulator with Backflow Function
10-
21-
Filter Regulator
Series
AW K-B
Series AW-B
10-
21-
1080
Air Preparation
Equipment
Pressure Control
Equipment
Flow Control
Equipment
Pressure Switches/
Pressure Sensors
Directional
Control Valves
Air Grippers
Modular F. R.
Fittings & Tubing
Air Cylinders
Rotary Actuators
A
Related Products
Email Part
Email How to Order Page
Products
- Actuators
-
Directional Control Valves
- Directional Control Valves Overview
- Solenoid Valves - 4 & 5 Port
- Solenoid Valves - 3 Port
- Solenoid Valves - Direct Operated
- Industrial Communication
- Air Operated Valves
- Mechanical & Hand Operated Valves
- Safety Pressure Relief Valves
- Solenoid Valves - ISO
- Clean Room Products
- Valve Manifold Configurator
- Airline Equipment
- Air Dryers & Main Line Filters
- Connectors
- Vacuum Products
- Industrial Communication
- Sensors & Switches
- Fluid Process
- Static Control
- Electric Actuators
- Chillers
- Process Gas Equipment
- High Vacuum
- Chemical Handling Equipment
- Secondary Battery