VIDEO:
30 SECOND
PART BUILDER
EXPLAINED
- SMC Home
- Directional Control Valves
- Solenoid Valves - 4 & 5 Port
- Legacy
- VQC 1000/2000
- 2000 Series
- Base Mount Plug-in
- Manifold, I/O SI Unit
VV5QC21-S, 2000 Series, Base Mounted Manifold, Plug-in, I/O Serial Transmission Unit (EX250)
The VQC series has five standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of three of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding response times and long life.
- Base mount EX250 type plug-in manifold for VQC2000 valve
- Protective enclosure conforms to IP67 for protection from
dust and moisture - I/O serial transmission kit reduces connection work,
minimizes wiring and saves space - Maximum 24 stations available as standard
- Optional DIN rail mount
- 18 port sizes available
How to order
DeviceNet
™
EX600 integrated-type (I/O) serial transmission system (Fieldbus system)
PROFIBUS DP
CC-Link
EtherNet/IP
™
PROFINET
EtherCAT
AABABABABABA
Base Mounted
How to Order Manifold
VQC1000 Series
·····
Enter EX250-compliant S kit only.
Enter EX600-compliant S kit only.
······ ··········
······
VV5QC 1 1
08
SDQ
Base mounted plug-in
VQC1000 series
01 1 station
C6
VV5QC 1 1
08
FD1
C6
PNP sensor input or without input block
NPN sensor input
Nil
N
Note) For the S kit compatible with AS-Interface, the
maximum number of stations is limited. Refer to
page 805 in Best Pneumatics No. 1-1 for details.
Nil
Without SI unit/input block (SD0)
Without input block
With 1 input block
With 8 input blocks
0
1
8
Note 1) Without SI unit, the symbol is nil.
Note 2) SI unit is not included in I/O unit stations.
Note 3) When I/O unit is selected, it is shipped
separately, and assembled by customer. Refer
to the attached operation manual for mounting
method.
Nil
None
1 station
9 stations
1
9
Nil
Without input block
M12, 2 inputs
M12, 4 inputs
M8, 4 inputs (3 pins)
1
2
3
T
·······
kit
·
F
·
P
·
S
·······
kit
ML
Nil
2
3
Without end plate
M12 connector power supply (Max. supply current 2A)
7/8 inch connector power supply (Max. supply current 8A)
Note) Without SI unit, the symbol is nil.
Nil
None
All stations with back pressure check valve
With DIN rail (Rail length: Standard)
Note 7)
With DIN rail (Rail length: Special)
Note 7)
Special wiring spec. (Except double wiring)
With name plate
External pilot
Direct EXH outlet with built-in silencer
B
Note 2)
D
D
Note 3)
K
Note 4)
N
Note 10)
R
Note 5)
S
Note 6)
Note 1) When two or more symbols are specified,
indicate them alphabetically. Example: -BRS
Note 2) When a back pressure check valve is desired,
and is to be installed only in certain manifold
stations, specify the mounting position by
means of the manifold specification sheet.
Note 3) For special DIN rail length, indicate “D”.
(Enter the number of stations inside .)
Example: -D08
In this case, stations will be mounted on a DIN
rail for 8 stations regardless of the actual num-
ber of manifold stations.
The specified number of stations must be larg-
er than the number of stations on the manifold.
Indicate “-D0” for the option without DIN rail.
Note 4) When single wiring and double wiring are
mixed, specify wiring type of each station by
means of the manifold specification sheet.
Note 5) For external pilot option, “-R”, indicate the ex-
ternal pilot specification “R” for the applicable
valves as well.
Note 6) Built-in silencer type does not satisfy IP67.
Note 7) When “Without SI unit (SD0, SD60)” is speci-
fied, “With DIN rail (D)” cannot be selected.
Note 8) When changing the specifications of the EX600
from no DIN rail to DIN rail mounting, please
consult SMC.
Note 9) DIN rail is not attached (but shipped together)
on the manifold in case of the EX600 with DIN
rail. Refer to back page 597 for mounting
method.
Note 10) When mounting the blanking plate with con-
nector and the slide locking manual type
valve by ordering only the manifold, order the
name plate separately. For details, refer to
page 589.
C3
C4
C6
M5
CM
L3
L4
L6
L5
B3
B4
B6
B5
LM
MM
Note 2)
With ø3.2 One-touch fitting
With ø4 One-touch fitting
With ø6 One-touch fitting
M5 thread
Mixed sizes and with port plug
Top ported elbow with ø3.2 One-touch fitting
Top ported elbow with ø4 One-touch fitting
Top ported elbow with ø6 One-touch fitting
M5 thread
Bottom ported elbow with ø3.2 One-touch fitting
Bottom ported elbow with ø4 One-touch fitting
Bottom ported elbow with ø6 One-touch fitting
M5 thread
Elbow port, mixed sizes (Including upward, downward piping and mixed)
Mixed size for different types of piping, option installed
Note 1) Indicate the size by means of the manifold
specification sheet in case of “CM”, “LM”, “NM”.
Note 2) When selecting the mixed size for different types
of piping or dual flow fitting assembly, enter “MM”
and give instructions in the manifold specification
sheet.
Note 3) Symbols for inch sizes are as follows:
N1: ø1/8" N3: ø5/32"
N7: ø1/4" NM: Mixed
The top ported elbow is LNand
the bottom ported elbow is BN.
Plug-in Unit
···
···
The maximum number of stations differs depending on
the electrical entry. (Refer to Kit type/Electrical
entry/Cable length.)
Note)
In case of compatibility with the S kit/AS-Interface, the
maximum number of solenoids is as shown below, so
please be careful of the number of stations.
•8in/8out:Maximum8solenoids
•4in/4out:Maximum4solenoids
······ ······
······
······
D side Stations
···
1
···
2
···
3
···
4
···
5
···
6
···
7
···
8
···
n U side
∗
Stations are counted from station 1 on the D-side.
Valve stations
Input block specification
(Enter EX250-compliant S kit only.)
Number of input blocks
(Enter EX250-compliant S kit only.)
I/O unit stations
(Enter EX600-compliant S kit only.)
Input block type
(Enter EX250-compliant S kit only.)
∗ Select “Nil” for without SI unit (SD0).
Nil
EX250 integrated-type (I/O) serial transmission system
SI unit
output polarity
Positive common
Negative common
N
Nil
DeviceNet
™
—
AS-Interface
—
CANopen
—
PROFIBUS DP
—
CC-Link
—
EtherNet/IP
™
—
SI unit
output polarity
Positive common
Negative common
N
SI unit output polarity
End plate type
(Enter EX600-compliant S kit only.)
Option
Cylinder port size
Nil
DeviceNet
™
EtherNet/IP
™
—
DeviceNet
™
EX500 Gateway Decentralized
System (64 points)
EX500 Gateway
Decentralized System 2
(128 points)
EX260 integrated-type (for output)
serial transmission system
EX126 integrated-type
(for output) serial
transmission system
EtherNet/IP
™
EtherNet/IP
™
EtherCAT
PROFIBUS DP
PROFIBUS DP
PROFINET
CC-Link
CC-Link
—
SI unit
output polarity
Positive common
Negative common
N
544
A
SD0
SDQ
SDN
SDV
SDTA
SDTB
SDTC
SDTD
SDY
SDZEN
Note 2)
Note 2)
1 to 12 stations
(24)
1 to 4 stations
(8)
1 to 2 stations
(4)
1 to 4 stations
(8)
1 to 2 stations
(4)
1 to 12 stations
(24)
Without SI unit
DeviceNet
™
PROFIBUS DP
CC-Link
CANopen
EtherNet/IP
™
AS-Interface,
8 in/8 out, 31 slave modes,
2 power supply systems
AS-Interface,
4 in/4 out, 31 slave modes,
2 power supply systems
AS-Interface,
8 in/8 out, 31 slave modes,
1 power supply systems
AS-Interface,
4 in/4 out, 31 slave modes,
1 power supply systems
S
kit
(Serial transmission:
EX500 gateway-type)
IP67 compliant
IP67 compliant
IP67 compliant
IP67 compliant
IP40 compliant
IP40 compliant
IP40 compliant
IP67 compliant
IP67 compliant
IP67 compliant
IP67 compliant
SI unit: EX500
Without SI unit
1 to 8 stations
(16)
S
kit
(Serial transmission
(Fieldbus system):
EX600 integrated-type (I/O))
SI unit: EX600
SD60
SD6Q
SD6N
SD6V
SD6F
SD6ZE
SD6EA
SD6D
Without SI unit
DeviceNet
™
PROFIBUS DP
CC-Link
PROFINET
EtherNet/IP™ (1 port)
EtherNet/IP™ (2 port)
EtherCAT
S
kit
(Serial transmission:
EX250 integrated-type (I/O))
SI unit: EX250
SI unit: EX126
S
kit
(Serial transmission:
EX126 integrated-type (for
output))
S
kit
(Serial transmission:
EX260 integrated-type (for output))
SDVB
1 to 8 stations
(16)
CC-Link
T
kit
(Terminal block box)
TD0
1 to 10 stations
(20)
Terminal block box
F
kit
(D-sub connector)
1 to 12 stations
(24)
1 to 12 stations
(24)
D-sub connector (25P) without cable
D-sub connector (25P) with 1.5 m cable
D-sub connector (25P) with 3.0 m cable
D-sub connector (25P) with 5.0 m cable
FD0
FD1
FD2
FD3
L
kit
(Lead wire)
1 to 12 stations
(24)
Lead wire (25 cores) 0.6 m lead wire
Lead wire (25 cores) 1.5 m lead wire
Lead wire (25 cores) 3.0 m lead wire
LD0
LD1
LD2
M
kit
(Circular connector)
1 to 12 stations
(24)
Circular connector (26P) without cable
Circular connector (26P) with 1.5 m cable
Circular connector (26P) with 3.0 m cable
Circular connector (26P) with 5.0 m cable
MD0
MD1
MD2
MD3
P
kit
(Flat ribbon cable)
1 to 12 stations
(24)
1 to 9 stations
(18)
Flat ribbon cable (26P) without cable
Flat ribbon cable (26P) with 1.5 m cable
Flat ribbon cable (26P) with 3.0 m cable
Flat ribbon cable (26P) with 5.0 m cable
Flat ribbon cable (20P) without cable
PD0
PD1
PD2
PD3
PDC
Note) For a 20P flat ribbon
cable, the cable
assembly must be
ordered separately.
∗The maximum number of stations displayed in parentheses is applied to the special wiring specifications. (Option “-K”)
Note 1) When using the SI unit with 32 outputs, use the GW unit compatible with the EX500 Gateway Decentralized System 2 (128 points).
Note 2) When selecting SI units with SDTC or SDTD specifications, there are limits to the supply current from the SI unit to the input block or valve. Refer to page 805 in Best
Pneumatics No. 1-1 for details.
Note 3) When selecting SI units with SDZCN specifications only, IP40 is compatible. (All other SI units are IP67 compliant.)
Note 4) For the SI unit part no., refer to page 546
SI unit: EX260
SD0
SQA
SQB
SNA
SNB
SNC
SND
SVA
SVB
SDA
SDB
SFA
SFB
SEA
SEB
DeviceNet™
PROFIBUS DP
CC-Link
EtherCAT
PROFINET
EtherNet/IP™
M12
M12
D-sub
Note 4)
M12
M12
M12
M12
32
16
32
16
32
16
32
16
32
16
32
16
32
16
Symbol Protocol
Number of
outputs
Communication
connector
Stations
2 to 12 stations (24)
2 to 8 stations (16)
2 to 12 stations (24)
2 to 8 stations (16)
2 to 12 stations (24)
2 to 8 stations (16)
2 to 12 stations (24)
2 to 8 stations (16)
2 to 12 stations (24)
2 to 8 stations (16)
2 to 12 stations (24)
2 to 8 stations (16)
2 to 12 stations (24)
2 to 8 stations (16)
Without SI unit
Kit type/Electrical entry/Cable length
∗Numbers in parentheses represent the maximum number of solenoids in case of mixed single and double wiring. The maximum
number of stations is determined by the total number of solenoids. When ordering mixed wiring, please add the option symbol “-K”.
SD0
SDA3
SDA2
——
EX500 Gateway Decentralized System (64 points)
DeviceNet
™
,PROFIBUS DP,
EtherNet/IP
™
EX500 Gateway Decentralized System 2 (128 points)
EtherNet/IP
™
16
outputs
32
outputs
Note 1)
1 to 12 stations
(24)
Note) A separate gateway
unit and communication
cable are required.
25 pins
26 pins
20 pins
25-core cable
26 pins
545
VQC1000 Series
Plug-in Unit
Base Mounted
SV
SYJ
SZ
VF
VP4
VQ
1/2
VQ
4/5
VQC
1/2
VQC
4/5
VQZ
SQ
VFS
VFR
VQ7
VQC
1/2
Related Products
- Airline Equipment
- Tubing
- Fittings
- Pressure & Vacuum Switches
- Cylinder Parts & Accessories
- Linear Actuators
Airline Equipment More →
Pressure & Vacuum Switches More →
Cylinder Parts & Accessories More →
Email Part
Email How to Order Page
Products
- Actuators
-
Directional Control Valves
- Directional Control Valves Overview
- Solenoid Valves - 4 & 5 Port
- Solenoid Valves - 3 Port
- Solenoid Valves - Direct Operated
- Industrial Communication
- Air Operated Valves
- Mechanical & Hand Operated Valves
- Safety Pressure Relief Valves
- Solenoid Valves - ISO
- Clean Room Products
- Valve Manifold Configurator
- Airline Equipment
- Air Dryers & Main Line Filters
- Connectors
- Vacuum Products
- Industrial Communication
- Sensors & Switches
- Fluid Process
- Static Control
- Electric Actuators
- Chillers
- Process Gas Equipment
- High Vacuum
- Chemical Handling Equipment
- Secondary Battery