CNA2 Accessory, I Type Single Knuckle Joint
The CNA2 series cylinder with lockĀ isĀ suitable for mid-stroke stops, emergency stops, and drop prevention. An equal holding force in extending and retracting directions make it possible to lock at either end of the stroke. High reliability and stable holding force are maintained by using a substantially lengthened brake shoe with superior wear resistance. The locking mechanism is isolated from lock release air, so lock function is not diminished by excessive dirt or drain in compressed air.
- Accessory: I type single knuckle joint
- Size: CNA2: 40, 50, 63, 80, 100
- Material: sulfur free cutting steel
How to order
JN
JN
M9BW
CNA2
With auto switch
CDNA2 L 50 100
Applicable Auto Switches/Refer to Best Pneumatics No. 3 for further information on auto switches.
L 50 100 D
D
A96
A93
A90
A54
A64
A33C
A34C
A44C
A59W
M9N
ā
M9P
ā
M9B
ā
J51
G39C
K39C
M9NW
ā
M9PW
ā
M9BW
ā
M9NA
M9PA
M9BA
ā
F59F
P3DW
ā
ā
ā
B54
B64
A33
A34
A44
B59W
ā
G59
ā
G5P
ā
K59
ā
G39
K39
ā
G59W
ā
G5PW
ā
K59W
ā
ā
ā
G5BA
G59F
ā
āā
DC AC
ā
ā
ā
Cylinder with Lock
Double Acting, Single Rod
Ćø40, Ćø50, Ćø63, Ćø80, Ćø100
Series CNA2
How to Order
Number of
auto switches
Nil
S
n
2 pcs.
1 pc.
ānā pcs.
With auto switch
(Built-in magnet)
Mounting
B
L
F
G
C
D
T
Basic
Axial foot
Rod flange
Head flange
Single clevis
Double clevis
Center trunnion
Cylinder stroke (mm)
Refer to the next page for standard stroke.
ā Auto switches are not
available with steel
tube.
Cylinder
tube material
Nil
F
ā
Aluminum tube
Steel tube
Locking direction
D
Both directions
With bellows/cushion
J
K
Nil
N
Nylon tarpaulin
Heat resistant tarpaulin
With double-side cushion
Without cushion
Bellows
Cushion
ā Lead wire length symbols: 0.5 m Ā·Ā·Ā·Ā·Ā·Ā· Nil (Example) M9NW
1 m Ā·Ā·Ā·Ā·Ā· M (Example) M9NWM
3 m Ā·Ā·Ā·Ā·Ā· L (Example) M9NWL
5 m Ā·Ā·Ā·Ā·Ā· Z (Example) M9NWZ
ā Solid state auto switches marked with āģā are produced upon receipt of order.
ā Since there are other applicable auto switches than listed, refer to page 28 for details.
ā For details about auto switches with pre-wired connector, refer to Best Pneumatics No. 3. Refer to CAT.ES20-201 catalog for the D-P3DW
ģ.
ā The D-A9ģ/M9ģģģ/P3DWģ auto switches are shipped together, (but not assembled). (Only auto switch mounting brackets are assembled at the time of shipment for the
D-A9ģ/M9ģģģ.)
Made to Order
Refer to the next
page for details.
ā For applicable auto switches,
refer to the below table.
Auto switch
Nil
Without auto switch
Thread type
Nil
TN
TF
Rc
NPT
G
Grommet
3-wire (NPN equivalent)
24 V
24 V
ā
24 V ā
2-wire
Yes
No
Yes
No
Yes
Yes
Terminal
conduit
Grommet
Diagnostic indication
(2-color indication)
Water resistant
(2-color indication)
With diagnostic output (2-color indication)
Diagnostic indication (2-color indication)
Magnetic field resistant (2-color indication)
Terminal
conduit
DIN terminal
Grommet
Grommet
5 V
12 V
ā
5 V, 12 V
12 V
ā
12 V
5 V, 12 V
12 V
5 V, 12 V
12 V
5 V, 12 V
ā
100 V
100 V or less
100 V, 200 V
200 V or less
ā
100 V, 200 V
ā
ā
100 V, 200 V
Relay,
PLC
PLC
Relay,
PLC
Relay,
PLC
ā
When the symbols are two or more, indicate them
alphabetically.
3-wire (NPN)
3-wire (NPN)
3-wire (NPN)
3-wire (NPN)
4-wire (NPN)
2-wire (Non-polar)
3-wire (PNP)
3-wire (PNP)
3-wire (PNP)
2-wire
2-wire
2-wire
2-wire
Built-in Magnet Cylinder Model
If a built-in magnet cylinder without an auto
switch is required, there is no need to enter
the symbol for the auto switch.
(Example) CDNA2L40-100-D
Reed auto switch
Solid state auto switch
IC circuit
ā
IC circuit
ā
IC circuit
ā
IC circuit
ā
IC circuit
ā
Bore size
40
50
63
80
100
40 mm
50 mm
63 mm
80 mm
100 mm
Pre-wired
connector
Applicable load
Auto switch model
Lead wire length (m)
Tie-rod
mounting
Band
mounting
0.5
(Nil)
3
(L)
5
(Z)
1
(M)
Type
Special function
Electrical
entry
Load voltage
Wiring
(Output)
Indicator light
3
Symbol
Double acting,
Single rod
Specifications
āXAģ
āXC3
āXC4
āXC11
āXC14
āXC15
āXC35
Change of rod end shape
Special port location
With heavy duty scraper
Dual stroke cylinder/Single rod
Change of trunnion bracket mounting position
Change of tie-rod length
With coil scraper
Symbol
Specifications
Caution
1. Each switch and mounting style of
cylinder has a different minimum
mountable stroke. Be especially careful
of the center trunnion style.
(Refer to pages 25 and 26 for details.)
Minimum mountable stroke for a
cylinder with auto switch(es)
40 50 63 80 100
Locking action
Unlocking pressure
Lock starting pressure
Max. operating pressure
Locking direction
Holding force (N)
Spring locking (Exhaust locking)
36 psi or more
29 psi or less
145 psi
Both directions
Lock type
Spring locking
Piston speed (mm/s)
100
Ā±0.3
300
Ā±0.6
500
Ā±1.0
1000
Ā±2.0
Condition: Lateral, Supply pressure P = 73 psi
Load weight Ā·Ā·Ā·Ā·Ā·Ā· Upper limit of allowed value
Solenoid valve for locking mounted on the unlocking port
Maximum value of stopping position dispersion from 100 measurements
(mm)
882 1370 2160 3430 5390
ā Load limits exist depending on the piston speed when locked, mounting direction and
operating pressure.
ā Be sure to select cylinders in accordance with the procedures on page 1.
Bore size (mm)
40
50, 63
80, 100
Standard stroke (mm)
Note 1)
Long stroke (mm)
Note 2)
25, 50, 75, 100, 125, 150, 175, 200, 250,
300, 350, 400, 450, 500
1200
Ćø80: 1400
Ćø100: 1500
800
25, 50, 75, 100, 125, 150, 175, 200, 250,
300, 350, 400, 450, 500, 600
25, 50, 75, 100, 125, 150, 175, 200, 250,
300, 350, 400, 450, 500, 600, 700
Lubrication
Action
Proof pressure
Max. operating pressure
Min. operating pressure
Piston speed
Cushion
Stroke length tolerance
Not required (Non-lube)
Double acting
218 psi
145 psi
12 psi
50 to 1000 mm/s
ā
Air cushion
Without auto switch: 15 to 160Ā°F (No freezing)
With auto switch: 15 to 140Ā°F (No freezing)
Basic, Axial foot, Rod flange, Head flange,
Single clevis, Double clevis, Center trunnion
40 50 63 80 100
Refer to pages 23 to 28 for cylinders with
auto switches.
ā¢ Minimum stroke for auto switch mounting
ā¢ Auto switch proper mounting position
(detection at stroke end) and mounting height
ā¢ Operating range
ā¢ Auto switch mounting bracket/Part no.
Bore size (mm)
Note 1) Intermediate strokes other than the above are produced upon receipt of order.
Spacers are not used for intermediate strokes.
Note 2) Long stroke applies to the axial foot and the rod flange.
When exceeding the stroke range for each bracket, determine the maximum stroke
referring to the Selection Table (front matter 29 in Best Pneumatics No. 2).
Up to 250: , 251 to 1000: , 1001 to 1500:
+1.0
0
+1.4
0
+1.8
0
Lock Specifications
Standard Stroke
For cases with auto switches, refer to the table of minimum stroke for
auto switch mounting on pages 25 and 26.
Stopping Accuracy
Bore size (mm)
Ambient and
fluid temperature
Mounting
Made to Order
(For details, refer to Best Pneumatics
No. 3.)
4
Series CNA2
Cylinder with Lock
Double Acting, Single Rod
Related Products
- Airline Equipment
- Speed Controllers
- Tubing
- Fittings
- Valves & Manifolds
- Pressure & Vacuum Switches
- Cylinder Parts & Accessories
- Floating joint PS
- 4/5 Valves PS
Airline Equipment More →
Speed Controllers More →
Valves & Manifolds More →
Pressure & Vacuum Switches More →
Cylinder Parts & Accessories More →
Floating joint PS More →
4/5 Valves PS More →
Email Part
Email How to Order Page
Products
- Actuators
-
Directional Control Valves
- Directional Control Valves Overview
- Solenoid Valves - 4 & 5 Port
- Solenoid Valves - 3 Port
- Solenoid Valves - Direct Operated
- Industrial Communication
- Air Operated Valves
- Mechanical & Hand Operated Valves
- Safety Pressure Relief Valves
- Solenoid Valves - ISO
- Clean Room Products
- Valve Manifold Configurator
- Airline Equipment
- Air Dryers & Main Line Filters
- Connectors
- Vacuum Products
- Industrial Communication
- Sensors & Switches
- Fluid Process
- Static Control
- Electric Actuators
- Chillers
- Process Gas Equipment
- High Vacuum
- Chemical Handling Equipment
- Secondary Battery